Ensotek — Kühlturm

Services

Planning, installation and maintenance

Cooling tower maintenance and repair service

Periodic Maintenance & Repair

Ensotek maintains cooling towers by verifying the performance of fills, spray nozzles, drift eliminators, fan group, motor-gearbox and mechanical assemblies. Vibration/noise checks, alignment, sealing and water distribution uniformity are validated on-site. The goal is to reduce downtime, stabilize approach temperature and extend equipment life.

Read more
Cooling tower modernization and retrofit

Modernization & Retrofit

Upgrade existing towers for capacity and efficiency: fill/nozzle upgrades, fan blade optimization, motor-gearbox revision, VFD integration, drift reduction and hydraulic improvements. Water distribution uniformity is targeted across the tower cross-section.

Read more
Cooling tower spare parts and components

Spare Parts & Critical Components

We match and supply catalog-aligned components: nozzle types, water distribution parts, PVC film fills / PP fills, drift eliminators, fan blades, motor-gearbox and mechanical fittings. Fast supply with optional installation/commissioning minimizes operational risk.

Read more
Cooling tower automation and SCADA

Automation, SCADA & Remote Monitoring

Monitor critical parameters such as flow, temperature, conductivity, level, energy consumption and vibration switch status. Build alarms and reporting to detect failures early and manage maintenance based on data.

Read more
Cooling tower engineering support

Engineering Support

We provide heat load analysis, sizing/selection, hydraulic balancing, performance assessment and technical documentation. Before/after measurements validate the target performance.

Read more
Cooling tower site survey and engineering

Site Survey & Engineering

On-site survey defines process conditions, layout, access platforms, water distribution architecture, fan group integration and mechanical requirements. Deliverables: selection/sizing, layout proposal, implementation plan and safety checklists.

Read more
Cooling tower performance optimization

Performance Optimization & Energy Efficiency

Measure approach temperature, fan efficiency, water distribution uniformity, drift loss and water chemistry. Optimize fills/nozzles, fan settings and operating setpoints to reduce energy costs and create a reportable KPI set.

Read more
Cooling tower commissioning and training

Commissioning & Startup

Coordinate installation, run checklists, test runs, vibration checks, water distribution tests and safe first startup. Deliver operator training and commissioning documentation.

Read more
Cooling tower emergency service

Emergency Service & Troubleshooting

Rapid diagnostics, replacement of critical parts (fan/motor/gearbox, nozzles, fills, drift eliminators) and safe restart. Followed by root cause analysis and preventive maintenance plan.

Read more

Solutions for your project

Contact us to discuss your requirements.

Contact us